Skip to content
Next Security

Security for systems that cannot fail.

Utilities, energy producers, ports and manufacturers are connecting control systems to enterprise networks, cloud analytics and vendor support. We review those connections and validate them with methods chosen for the process they protect, under written approval.

The situation

Industrial environments were designed around availability and physical safety, with security provided by isolation. That isolation is now crossed on purpose: historians replicate to the enterprise network, vendors support equipment remotely, IIoT sensors report to cloud platforms, and new products ship with connected interfaces and OTA updates.

Each of those paths serves a business need, so the goal is to make them deliberate: known, narrow, monitored and owned. Testing here follows different rules from IT. A port scan that is routine on an office network can crash a PLC or an older HMI.

What goes wrong

The failure modes we look for first in this sector. Each one becomes a test case against your system.

Flat networks behind the firewall
The boundary to the enterprise is filtered, but inside the OT network every workstation can reach every controller. One compromised engineering laptop reaches the whole process.
Vendor access that never closes
Remote support connections stay up permanently, use shared accounts or bypass the jump host, and nobody reviews who used them or when.
Dual-homed hosts
An engineering workstation or historian has interfaces on both the enterprise and control networks, bridging the segments the firewall was meant to separate.
Unauthenticated control protocols
Many industrial protocols run without authentication in typical deployments. Anyone with network reach to the device can read values or issue writes.
An inventory that no longer matches reality
Segmentation rules and patch decisions are based on a drawing that does not reflect what is actually connected.
Connected products with weak update integrity
Field devices accept unsigned firmware or keep default credentials set at manufacture.

How we work in this sector

Architecture, then Segmentation, then Access workflows, then Safe validation. Each stage feeds the next, and the same team carries the context through.

  1. 1

    Architecture

    Build an accurate picture of zones, conduits and data flows from documentation, configuration exports and interviews with operations staff. Where you work to IEC 62443, we use its zone and conduit model.

  2. 2

    Segmentation

    Assess firewall rules and routing between zones against what the process needs. Find dual-homed hosts and paths that bypass the DMZ.

  3. 3

    Access workflows

    Review how staff and vendors get in: request, approval, session recording, time limits, revocation. Design a workflow operations can live with.

  4. 4

    Safe validation

    Confirm findings with techniques approved per zone: configuration review and passive analysis first, active testing only on agreed targets in agreed windows, or on lab or spare equipment.

Safety and rules of engagement

Operational safety comes before test coverage. Every OT engagement runs under these conditions.

  • Nothing active runs in an OT network without a written safety assessment, written rules of engagement, and sign-off from the asset owner and the operations lead responsible for the process.
  • Default methods are passive: configuration and firewall rule review, architecture documentation, and traffic captures you provide or that we take from a SPAN port with approval.
  • Active scanning or protocol interaction is limited to named targets, at agreed rates, in maintenance windows or on a test environment, with operations staff present and able to stop the test.
  • No writes to controllers, firmware changes or logic changes on live equipment. Anything that needs those runs on spare or lab equipment.
  • We do not sell a generic SCADA penetration test. Each engagement is scoped to the specific site, process and risk tolerance, and the report states what was not tested.

Relevant services

Questions buyers in this sector ask

Can you test a connected industrial system without harming operations?

Yes, when the scope is built around the process. Most findings come from configuration, architecture and access review, which touch nothing live. Active tests run only on approved targets, at limited rates, in agreed windows or on replica equipment, with operations able to stop them. If a test cannot be done safely, it is left out and recorded as untested.

Do you work to IEC 62443?

We use its zone and conduit model and security level concepts to structure findings when your organization works to the standard. We do not certify against it.

We build connected devices rather than run plants. Does this apply?

Yes. Firmware update integrity, device identity and provisioning, and the cloud services the devices talk to are part of the same work. We usually start with a threat model of the device lifecycle, from manufacture to decommissioning.

Start with what can be tested safely

Describe the site or product and its constraints. The first conversation covers scope, safety conditions and who needs to approve what.